Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 13, 2018, 07:41 AM
  • 08 0035_08 0034 _13042018_005502.mp4

Date
04/13/2018
W/O
694025
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00016
PipeID
P00037
Time
12:41 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5529
Sewer Name
08 MAIN STREET TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
WO_694025_TV08116_APR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
08 0035
Downstream MH
08 0034
Dir. of Survey
Downstream
Length Surveyed
327.6 ft.
Total Length
327.7 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
138
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
3
Overall Quick
Overall Rating
139
Pipe schematic from manhole 08 0035 to 08 0034
MH: 08 0035MH: 08 0034downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 003511.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"62.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"98.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start112.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"165.2 ft. RFL - Roots Fine Lateral, at 12 o'clock165.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"212.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"261.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"313.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"327.7 ft. AMH - Downstream Manhole, Survey Ends - 08 0034327.7 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK327.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    98.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (15)

DistanceCodeObservation
0MWL
327.7AMH08 0034
313.4TFC
165.2RFL
212.2TFC
62.9TFC
11.5TF
165.2TF
261.9TF
327.7MGOCONNECTION AT MH 3 O'CLOCK
0MWM
327.7CM
98.6CM
112.8TFC
0AMH08 0035

Properties (6)

additional_info
SC358736
custom_field_two
3
customer
LACSD
datetime
2018-04-13T00:41:47-07:00
documentation
PROPIPE
is_lateral_inspection
false