Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 10, 2018, 11:26 AM
  • 08 0093_08 0092 _10042018_043604.mp4

Date
04/10/2018
W/O
694025
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00016
PipeID
P00121
Time
4:26 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5526
Sewer Name
08 MAIN STREET TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
01
Purpose
Routine Assessment
Project
WO_694025_TV08116_APR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
08 0093
Downstream MH
08 0092
Dir. of Survey
Downstream
Length Surveyed
314.2 ft.
Total Length
314.2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 08 0093 to 08 0092
MH: 08 0093MH: 08 0092downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 00930 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 55 %of cross sectional area5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start69.6 ft. TS - Tap Saddle, at 12 o'clock, -, within 8 inches of joint: NO, 6"169.7 ft. TSC - Tap Saddle Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"269.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"311.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish314.2 ft. AMH - Downstream Manhole, Survey Ends - 08 0092314.2 ft. MGO - General Observation - SERVICE CONNECTION AT 3 O' CLOCK AT MH314.2 ft. MGO - General Observation - SERVICE CONNECTION AT 9 O'CLOCK AT MH

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
269.7TFC
0AMH08 0093
311.3CM
169.7TSC
0MWL
314.2AMH08 0092
0MWM
314.2MGOSERVICE CONNECTION AT 3 O' CLOCK AT MH
5CM
314.2MGOSERVICE CONNECTION AT 9 O'CLOCK AT MH
69.6TS

Properties (6)

additional_info
SC358733
custom_field_two
3
customer
LACSD
datetime
2018-04-10T04:26:49-07:00
documentation
PROPIPE
is_lateral_inspection
false