Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 30, 2017, 08:14 AM
  • 02 0301_02 0300_6302017_012119.mp4

Date
06/30/2017
W/O
0647471
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00251
PipeID
P02615
Time
1:14 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0581
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
22A
Purpose
Routine Assessment
Project
20170626MDM_DOWNEY_BELLFLOWER_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0300
Downstream MH
02 0301
Dir. of Survey
Upstream
Length Surveyed
155.8 ft.
Total Length
155.8 ft.
Structural Index
2
Structural Quick
4136
Structural Rating
70
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
74
Pipe schematic from manhole 02 0300 to 02 0301
MH: 02 0300MH: 02 0301upstream0 ft. AMH - Upstream Manhole, Survey Ends - 1:50AM0.3 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active12.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H21.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H33.5 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - H33.5 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - H37.4 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H41.7 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - H45.4 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H53.6 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H61.8 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H66.3 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H78.2 ft. FC - Fracture Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES - H83.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped85.1 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - H89.3 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H97.5 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H97.5 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - SL101.4 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H101.4 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H105.6 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - H105.6 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - H109.7 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H117.7 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H117.7 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H121.9 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H125.8 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SL129.6 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H133.7 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H137.6 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H141.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H145.9 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SLIGHT145.9 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SLIGHT150 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - HAIRLINE155.8 ft. MWM - Water Mark, 50 %of cross sectional area155.8 ft. MWL - Water Level, 50 %of cross sectional area155.8 ft. AMH - Downstream Manhole, Survey Begins - 1:15AM

Observations (37)

DistanceCodeObservation
50.2FCH
0MWM
114.1FCH
122.3FCH
72.7TFCCapped
70.7FCH
66.5FCH
26.2FCH
0MWL
38.1FLH
50.2FCH
30FMSL
58.3FCH
33.9FCH
38.1FCH
9.9FCSLIGHT
46.1FCH
155.5MGOConn. @ Mh, 9 O' Clock. Active
77.6FCH
0AMH1:15AM
122.3FCH
134.5FLH
18.2FCH
58.3FLSL
118.4FCH
22.1FCH
14FLH
110.4FCH
102.2FCH
143FLH
9.9FCSLIGHT
94FCH
54.4FLH
89.5FCH
54.4FCH
5.8FCHAIRLINE
155.8AMH1:50AM

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2017-06-30T01:14:40-07:00
documentation
MARTIN,MANANES,OLIVER 111
is_lateral_inspection
false