01 1187_01 1186_05222019_034705.mp4
0 ft. - General Observation - COCKROACHES IN MANHOLE
2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start
5.8 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
45.3 ft. - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES
70.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
132.8 ft. - General Observation - FLOW METER AT MH.
132.8 ft. - General Observation - COCKROACHES IN MANHOLE
| Distance | Code | Observation |
|---|---|---|
| 132.7 | MGO | Connection at 3'0 and 9'0 in MH |
| 0 | MGO | COCKROACHES IN MANHOLE |
| 132.8 | MGO | FLOW METER AT MH. |
| 132.8 | AMH | 01 1186 |
| 0 | MWL | — |
| 45.3 | FL | — |
| 130.4 | SAP | — |
| 0 | AMH | 01 1187 |
| 70.5 | FM | — |
| 130.4 | FM | — |
| 130.4 | DAGS | — |
| 0 | MGO | CONNECTIONS IN MH AT BOTH 3 AND 9 O' CLOCK |
| 132.8 | MGO | COCKROACHES IN MANHOLE |
| 2 | DAGS | — |
| 0 | MWM | — |
| 5.8 | SAP | — |