Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 15, 2019, 09:50 AM
  • G 0141_G 0140_02152019_022500.mp4

Date
02/15/2019
W/O
745594
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z01180
PipeID
P01464
Time
1:50 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6275
Sewer Name
G JOINT OUTFALL G - UNIT 8
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_745594_TV01236_JAN2019
Sewer Type
Gravity
Material
RCP-CTL
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
G 0141
Downstream MH
G 0140
Dir. of Survey
Downstream
Length Surveyed
345.3 ft.
Total Length
345.3 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
5
Overall Quick
Overall Rating
9
Pipe schematic from manhole G 0141 to G 0140
MH: G 0141MH: G 0140downstream0 ft. MWM - Water Mark, 95 %of cross sectional area0 ft. MWL - Water Level, 70 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - G 01416 ft. MB - Missing Brick, from 09 to 03 o'clock, Start339.9 ft. MB - Missing Brick, from 09 to 03 o'clock, Finish345.2 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK CAPPED345.3 ft. AMH - Downstream Manhole, Survey Ends - G 0140345.3 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK CAPPED

Observations (8)

DistanceCodeObservation
6MB
0MWM
0MWL
345.3AMHG 0140
345.2MGOCONNECTION AT MH 3 O'CLOCK CAPPED
339.9MB
345.3MGOCONNECTION AT MH 9 O'CLOCK CAPPED
0AMHG 0141

Properties (4)

custom_field_two
1
customer
LACSD
datetime
2019-02-15T01:50:57-08:00
is_lateral_inspection
false