Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 18, 2019, 10:30 AM
  • G 0153_G 0152_02182019_025808.mp4

Date
02/18/2019
W/O
745594
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z01180
PipeID
P01476
Time
2:30 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6276
Sewer Name
G JOINT OUTFALL G - UNIT 8
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
17
Purpose
Routine Assessment
Project
RFIR_WO_745594_TV01236_JAN2019
Sewer Type
Gravity
Material
RCP-CTL
Shape
Square
Height
36 in.
Width
36 in.
Upstream MH
G 0153
Downstream MH
G 0152
Dir. of Survey
Downstream
Length Surveyed
358.7 ft.
Total Length
358.7 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
5
Overall Quick
Overall Rating
9
Pipe schematic from manhole G 0153 to G 0152
MH: G 0153MH: G 0152downstream0 ft. MWL - Water Level, 75 %of cross sectional area0 ft. MWM - Water Mark, 95 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - G 015318.3 ft. MB - Missing Brick, from 09 to 03 o'clock, Start53.6 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 8"102.5 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 8"358.4 ft. MB - Missing Brick, from 09 to 03 o'clock, Finish358.7 ft. AMH - Downstream Manhole, Survey Ends - G 0152

Observation photos (1)

  • Missing Brick, from 09 to 03 o'clock, Start

    18.3 ft. - Missing Brick, from 09 to 03 o'clock, Start

Observations (9)

DistanceCodeObservation
0MWL
358.7AMHG 0152
358.4MB
102.5TFA
0MWM
0MGOCONNECTION AT MH 9 O'CLOCK
53.6TFA
0AMHG 0153
18.3MB

Properties (4)

custom_field_two
1
customer
LACSD
datetime
2019-02-18T02:30:41-08:00
is_lateral_inspection
false