Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 18, 2017, 11:37 PM
  • A 0843C 0569District 03_102317.mp4

Date
10/18/2017
W/O
668756
Weather
Dry
Operator/Surveyor
ERU
Sewer ID
Z00362
PipeID
P05252
Time
4:37 PM
Certificate
123456
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5111
Sewer Name
C JOINT OUTFALL C - UNIT 4D
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
08
Purpose
Routine Assessment
Project
WO_668756_TV03084_NOV2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
C 0569
Downstream MH
A 0843
Dir. of Survey
Upstream
Length Surveyed
333 ft.
Total Length
333 ft.
Structural Index
3
Structural Quick
3321
Structural Rating
11
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
15
Pipe schematic from manhole C 0569 to A 0843
MH: C 0569MH: A 0843upstream0 ft. AMH - Upstream Manhole, Survey Ends - A 08433.7 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish198.4 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES209.8 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES277.6 ft. CM - Crack Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES327.2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start333 ft. MWL - Water Level, 35 %of cross sectional area333 ft. AMH - Downstream Manhole, Survey Begins - C 0569333 ft. MWM - Water Mark, 50 %of cross sectional area

Observation photos (4)

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    5.8 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES

    55.4 ft. - Crack Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    123.2 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    134.6 ft. - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

Observations (9)

DistanceCodeObservation
329.3SSS
0MWL
0AMHC 0569
5.8SSS
123.2CM
134.6CM
55.4CM
333AMHA 0843
0MWM

Properties (5)

custom_field_two
CR3
customer
LACSD
datetime
2017-10-18T16:37:58-07:00
documentation
PROPIPE
is_lateral_inspection
false