Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 24, 2017, 07:29 AM
  • 08 0465_08 0464 _23012017_232916.mpg

Date
01/23/2017
W/O
619884
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00026
PipeID
P00521
Time
11:29 PM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4088
Sewer Name
08 216TH STREET TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
WO_NA_TV_NA_EMERGENCY_WORK_FEB2017
Sewer Type
Gravity
Material
RCP-CTL
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
08 0465
Downstream MH
08 0464
Dir. of Survey
Downstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
5
O&M Quick
5200
O&M Rating
10
Overall Index
4
Overall Quick
Overall Rating
13
Pipe schematic from manhole 08 0465 to 08 0464
MH: 08 0465MH: 08 0464downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 04650 ft. MWL - Water Level, 80 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK ACTIVE0 ft. MWM - Water Mark, 80 %of cross sectional area2.1 ft. MSA - Survey Abandoned - WATER LEVEL FLOW HIGH2.1 ft. OBZ - Obstacles Other, 40 %of cross sectional area, from 03 to 09 o'clock - DEBRIS NOT VISIBLE2.1 ft. MGO - General Observation - MAGNESIUM H.O.2.1 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES

Observation photos (2)

  • Survey Abandoned - WATER LEVEL FLOW HIGH

    2.1 ft. - Survey Abandoned - WATER LEVEL FLOW HIGH

  • Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES

    2.1 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
0AMH08 0465
0MWL
2.1MSAWATER LEVEL FLOW HIGH
0MGOCONNECTION AT MH 3 O'CLOCK ACTIVE
2.1OBZDEBRIS NOT VISIBLE
0MWM
2.1MGOMAGNESIUM H.O.
2.1SAV