Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 10, 2017, 08:21 AM
  • 02 1561_02 1560__081017_013839.mp4

Date
08/10/2017
W/O
646537
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00230
PipeID
P03993
Time
1:21 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4680
Sewer Name
02 ARIZONA AVENUE TRUNK, SECTION 1
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
V
Project
WO_646537_TV02004_JUL2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1561
Downstream MH
02 1560
Dir. of Survey
Downstream
Length Surveyed
318.1 ft.
Total Length
318.1 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole 02 1561 to 02 1560
MH: 02 1561MH: 02 1560downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 15610 ft. MWM - Water Mark, 35 %of cross sectional area2.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start5.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start57.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"58.4 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 4"98.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"139 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"144.4 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 4"177.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"217.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"220.6 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 4"263.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"269.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"309.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"318.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish318.1 ft. AMH - Downstream Manhole, Survey Ends - 02 1560318.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (19)

DistanceCodeObservation
0MWL
177.3TF
318.1FM
0AMH02 1561
2.8DAGS
139TBC
318.1AMH02 1560
144.4TB
58.4TB
318.1DAGS
309.5TF
269.1TF
98.5TF
263.7TF
220.6TB
217.7TFC
5.5FM
0MWM
57.8TFC

Properties (6)

additional_info
SC345619
custom_field_two
4
customer
LACSD
datetime
2017-08-10T01:21:43-07:00
documentation
PROPIPE
is_lateral_inspection
false