Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 30, 2017, 05:06 PM
  • Section#2_05 2615_05 2614__8302017__G6812.mp4

Date
08/30/2017
W/O
0651131
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z01145
PipeID
P25706
Time
10:06 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
G6812
Sewer Name
05 MANCHESTER AVENUE PUMP RELIEF TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Maintenance Related
Project
20170830SHO_MANCHESTER_AVENUE_PUMP_RELIEF_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
36 in.
Upstream MH
05 2614
Downstream MH
05 2615
Dir. of Survey
Upstream
Length Surveyed
36.7 ft.
Total Length
36.7 ft.
Structural Index
2
Structural Quick
2700
Structural Rating
14
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
18
Pipe schematic from manhole 05 2614 to 05 2615
MH: 05 2614MH: 05 2615upstream0 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish0 ft. MSA - Survey Abandoned - TOO MUCH DEBRIS33.7 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start36.7 ft. MWM - Water Mark, 55 %of cross sectional area36.7 ft. AMH - Downstream Manhole, Survey Begins - 101036.7 ft. MWL - Water Level, 40 %of cross sectional area

Observations (6)

DistanceCodeObservation
36.7SSS
3SSS
0MWM
0AMH1010
36.7MSATOO MUCH DEBRIS
0MWL

Properties (7)

additional_info
LOOKING FOR DAMAGE TO THE CROWN OF THE PIPE
custom_field_three
CAN'T GET OVER DEBRIS
custom_field_two
1
customer
LACSD
datetime
2017-08-30T10:06:38-07:00
documentation
OBREGON, IGNACIO, FRANKLIN, BRAR, MIRANDA
is_lateral_inspection
false