Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 12, 2019, 12:03 PM
  • J 0491_J 0226_6122019_050945.mp4

Date
06/12/2019
W/O
0756080
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00057
PipeID
P24756
Time
5:03 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1231
Sewer Name
J JOINT OUTFALL J - UNIT 1E
City
PALO VERDES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
47
Purpose
Routine Assessment
Project
20190612MDM_JOINT_OUTFALL_J_UNIT_1E
Material
PEP
Shape
Circular
Height
30 in.
Upstream MH
J 0491
Downstream MH
J 0226
Dir. of Survey
Downstream
Length Surveyed
11.1 ft.
Total Length
11.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole J 0491 to J 0226
MH: J 0491MH: J 0226downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins( ABANDSONED MH) - 5:10AM( ABANDONED MH)0 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. MGO - General Observation - PIPE APPEARS AS 48" RGRCP3.6 ft. MGO - General Observation - 48" RGRCP11.1 ft. AMH - Downstream Manhole, Survey Ends - 5:15AM

Observation photos (3)

  • Upstream Manhole, Survey Begins( ABANDSONED MH) - 5:10AM( ABANDONED MH)

    0 ft. - Upstream Manhole, Survey Begins( ABANDSONED MH) - 5:10AM( ABANDONED MH)

  • General Observation - PIPE APPEARS AS 48" RGRCP

    2 ft. - General Observation - PIPE APPEARS AS 48" RGRCP

  • General Observation - 48" RGRCP

    3.6 ft. - General Observation - 48" RGRCP

Observations (6)

DistanceCodeObservation
0MWL
2MGOPIPE APPEARS AS 48" RGRCP
0AMH5:10AM( ABANDONED MH)
11.1AMH5:15AM
3.6MGO48" RGRCP
0MWM

Properties (7)

additional_info
PIPE APPEARS 48" RGRCP
custom_field_three
48" RGRCP GOOD COND
custom_field_two
4
customer
LACSD
datetime
2019-06-12T05:03:40-07:00
documentation
MARTIN,REVELES,OLIVER 111,SHADLER
is_lateral_inspection
false