Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 11, 2019, 10:19 AM
  • B 1356_B 1355_6112019_034742.mp4

Date
06/11/2019
W/O
0771792
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01126
PipeID
P25068
Time
3:19 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1229
Sewer Name
B JOINT OUTFALL B - UNIT 6J
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
08
Purpose
Routine Assessment
Project
20190610MDM_JOINT_OUTFALL_B_UNIT_6J
Material
Vitrified Clay Pipe
Shape
Circular
Height
16 in.
Upstream MH
B 1356
Downstream MH
B 1355
Dir. of Survey
Downstream
Length Surveyed
232.1 ft.
Total Length
232.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole B 1356 to B 1355
MH: B 1356MH: B 1355downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:45AM0 ft. MWM - Water Mark, 20 %of cross sectional area8.1 ft. MGO - General Observation - 16" VCP + CIPP53.3 ft. LFB - Lining Failure Blistered, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SMALL POPPING BLISTERS139.8 ft. LFB - Lining Failure Blistered, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SMALL POPPING BLISTERS203.8 ft. MGO - General Observation - WHITE BUILDUP ON PIPE232.1 ft. AMH - Downstream Manhole, Survey Ends - 4:05AM

Observation photos (2)

  • General Observation - 16" VCP + CIPP

    8.1 ft. - General Observation - 16" VCP + CIPP

  • General Observation - WHITE BUILDUP ON PIPE

    203.8 ft. - General Observation - WHITE BUILDUP ON PIPE

Observations (8)

DistanceCodeObservation
0MWL
203.8MGOWHITE BUILDUP ON PIPE
0AMH3:45AM
139.8LFBSMALL POPPING BLISTERS
0MWM
53.3LFBSMALL POPPING BLISTERS
232.1AMH4:05AM
8.1MGO16" VCP + CIPP

Properties (7)

custom_field_three
CIPP LINER SMALL POPPING BLISTERS
custom_field_two
4
customer
LACSD
datetime
2019-06-11T03:19:39-07:00
documentation
MARTIN,REVELES,OLIVER 111,SHADLER
is_lateral_inspection
false
lining
CIPP