Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 10, 2019, 08:03 AM
  • 17 0073_17 0072_6102019_011456.mp4

Date
06/10/2019
W/O
#
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00668
PipeID
P13792
Time
1:03 AM
Certificate
U-104-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1227R
Sewer Name
17 DISTRICT #17 MAIN TRUNK
City
ALTADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
03
Purpose
Maintenance Related
Project
20190610MDM_DISTRIC_17_MAIN_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
17 0073
Downstream MH
17 0072
Dir. of Survey
Downstream
Length Surveyed
335.7 ft.
Total Length
335.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
4121
O&M Rating
8
Overall Index
2
Overall Quick
Overall Rating
8
Pipe schematic from manhole 17 0073 to 17 0072
MH: 17 0073MH: 17 0072downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:15AM0 ft. MWL - Water Level, 10 %of cross sectional area179 ft. MGO - General Observation - 12" VCP207 ft. MWM - Water Mark, 55 %of cross sectional area254.3 ft. RFJ - Roots Fine Joint, from 07 to 12 o'clock, within 8 inches of joint: YESR - 2%255.5 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: YES, 6" - Open258.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped266.1 ft. RFJ - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YESR - 4%276.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start335.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish335.2 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active335.7 ft. AMH - Downstream Manhole, Survey Ends - 1:35AM

Observation photos (2)

  • General Observation - 12" VCP

    179 ft. - General Observation - 12" VCP

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    276.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
207MWM
276.1DAGS
0MWM
0AMH1:15AM
335.7AMH1:35AM
266.1RFJ4%
255.5TBOpen
254.3RFJ2%
179MGO12" VCP
258.5TFCCapped
335.2DAGS
335.2MGOConn. @ Mh, 9 O' Clock. Active
0MWL

Properties (5)

additional_info
ROOT EVALUATION ONLY
customer
LACSD
datetime
2019-06-10T01:03:51-07:00
documentation
MARTIN,REVELES,OLIVER 111,SHADLER
is_lateral_inspection
false