Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 7, 2019, 08:57 PM
  • Section#1_29 0519A_29 0519__672019__I0156.mp4

Date
06/07/2019
W/O
0771885
Weather
Dry
Operator/Surveyor
IGNACIO
Sewer ID
Z01106
PipeID
P24571
Time
1:57 PM
Certificate
PENGIND
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0156
Sewer Name
29 19TH STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Capital Improvement Program Assesment
Project
20190607MI_19_TH_STREET_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0519
Downstream MH
29 0519A
Dir. of Survey
Upstream
Length Surveyed
290.3 ft.
Total Length
290.3 ft.
Structural Index
2
Structural Quick
2J11
Structural Rating
115
O&M Index
4
O&M Quick
5121
O&M Rating
7
Overall Index
2
Overall Quick
Overall Rating
122
Pipe schematic from manhole 29 0519 to 29 0519A
MH: 29 0519MH: 29 0519Aupstream0 ft. AMH - Upstream Manhole, Survey Ends - 02:40 PM1.6 ft. DSGV - Deposits Settled Gravel, 40 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES1.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4" - OPEN5.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"22.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"40.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"45.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"96.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"108.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"147.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"149.9 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 4"203.4 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 4" - OPEN209.3 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 4"223 ft. JOM - Joint Offset Medium, 0.5"247.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"250.3 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 4"271.2 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 4" - 50% BLOCKED287.3 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"288.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start290.3 ft. MWL - Water Level, 15 %of cross sectional area290.3 ft. AMH - Downstream Manhole, Survey Begins - 02:00 PM290.3 ft. MGO - General Observation - ROACHES >50 AT MH290.3 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (4)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 4" - 50% BLOCKED

    19.1 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 4" - 50% BLOCKED

  • Deposits Settled Gravel,  40 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES

    288.7 ft. - Deposits Settled Gravel, 40 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES

  • Upstream Manhole, Survey Ends - 02:40 PM

    290.3 ft. - Upstream Manhole, Survey Ends - 02:40 PM

Observations (24)

DistanceCodeObservation
288TFOPEN
267.4TFC
0MWL
140.4TFA
288.7DSGV
86.9TFOPEN
0AMH02:00 PM
3TFC
193.4TFC
288.7SSS
67.3JOM
244.6TFC
249.5TFA
19.1TFD50% BLOCKED
81TFA
2SSS
40TFA
143.2TFA
0MGOROACHES >50 AT MH
290.3AMH02:40 PM
0MWM
285TFA
181.7TFA
42.6TFC

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-06-07T13:57:08-07:00
documentation
IGNACIO, BRAR
is_lateral_inspection
false