- Date
- 08/31/2018
- W/O
- 0723688
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00210
- PipeID
- P02226
- Time
- 1:02 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0967
- Sewer Name
- 01 HUNTINGTON PARK TRUNK
- City
- HUNTINGTON PARK
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 08
- Purpose
- Routine Assessment
- Project
- 20180831MDM_HUNTINGTON_PARK_TRUNK_
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Upstream MH
- 01 0716
- Downstream MH
- 01 1096
- Dir. of Survey
- Downstream
- Length Surveyed
- 332.8 ft.
- Total Length
- 332.8 ft.
- Structural Index
- 2
- Structural Quick
- 2100
- Structural Rating
- 2
- O&M Index
- 4
- O&M Quick
- 5241
- O&M Rating
- 18
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 20
Pipe schematic from manhole 01 0716 to 01 1096 Observation photos (7)

4 ft. - General Observation - STOPLOG NOTCH 3:00

4 ft. - General Observation - OPENING TO MH H106 LEFT SIDE

4 ft. - General Observation - STOPLOG NOTCH 9:00

9 ft. - General Observation - 21" VCP

85.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start

127.2 ft. - Water Mark, 90 %of cross sectional area

135.9 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 10 to 02 o'clock, , within 8 inches of joint: YES, Start