Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 28, 2018, 12:19 PM
  • 01 1098_H 0110_8282018_052231.mp4

Date
08/28/2018
W/O
0723688
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00210
PipeID
P02230
Time
5:19 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0959
Sewer Name
01 HUNTINGTON PARK TRUNK
City
HUNTINGTON PARK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
07
Purpose
Routine Assessment
Project
20180828MDM_HUNTINGTON_PARK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
01 1098
Downstream MH
H 0110
Dir. of Survey
Downstream
Length Surveyed
152.9 ft.
Total Length
152.9 ft.
Structural Index
2
Structural Quick
322A
Structural Rating
28
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
32
Pipe schematic from manhole 01 1098 to H 0110
MH: 01 1098MH: H 0110downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 5:25AM0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active7.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE8 ft. MGO - General Observation - 18" VCP15.1 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - H17.6 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - SLIGHT26.6 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open-99% GREASE45.7 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - SL53.5 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H56.1 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - H61.5 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - SL77.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open127 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open-99& GREASE128.1 ft. FC - Fracture Circumferential, from 11 to 12 o'clock, within 8 inches of joint: YES - SL133.6 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - SL135.9 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SL135.9 ft. FC - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES - SL135.9 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H141.8 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - SL152 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active152.9 ft. AMH - Downstream Manhole, Survey Ends - 5:40AM

Observation photos (1)

  • General Observation - 18" VCP

    8 ft. - General Observation - 18" VCP

Observations (23)

DistanceCodeObservation
8MGO18" VCP
15.1FCH
0MWL
0MWM
17.6FCSLIGHT
0AMH5:25AM
77.8TFOpen
26.6TFDOpen-99% GREASE
152.9AMH5:40AM
53.5FCH
7.4FLHAIRLINE
135.9FLSL
127TFDOpen-99& GREASE
128.1FCSL
141.8FCSL
133.6FCSL
152MGOConn. @ Mh, 9 O' Clock. Active
0MGOConn. @ Mh, 9 O' Clock. Active
61.5FCSL
56.1FCH
135.9FCSL
135.9FCH
45.7FCSL

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
4
customer
LACSD
datetime
2018-08-28T05:19:03-07:00
documentation
MARTIN,REVELES,OLIVER 111,YOUNG
is_lateral_inspection
false