Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 27, 2018, 08:49 AM
  • 01 1132_01 1131_8272018_024419.mp4

Date
08/27/2018
W/O
0723688
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00210
PipeID
P01984
Time
1:49 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0955
Sewer Name
01 HUNTINGTON PARK TRUNK
City
HUNTINGTON PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
04
Purpose
Routine Assessment
Project
20180827MDM_HUNTINGTON_PARK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
01 1131
Downstream MH
01 1132
Dir. of Survey
Upstream
Length Surveyed
204.2 ft.
Total Length
204.2 ft.
Structural Index
2
Structural Quick
372A
Structural Rating
43
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
43
Pipe schematic from manhole 01 1131 to 01 1132
MH: 01 1131MH: 01 1132upstream0 ft. AMH - Upstream Manhole, Survey Ends - 3:10AM12.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open14.4 ft. FC - Fracture Circumferential, from 11 to 02 o'clock, within 8 inches of joint: YES - H20.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open26.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open36.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open58 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H70.8 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H77.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open82.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Active99 ft. FC - Fracture Circumferential, from 10 to 03 o'clock, within 8 inches of joint: YES - H111.9 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H111.9 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H114.3 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H121.8 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H124.8 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H125.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped128.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open132.4 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H137.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H145.4 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL168.2 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - H178.5 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H182.3 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H183.6 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - SL191.3 ft. FC - Fracture Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES - HAIRLINE191.3 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SLIGHT196.2 ft. MGO - General Observation - 15" VCP204.2 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN204.2 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. OPEN204.2 ft. AMH - Downstream Manhole, Survey Begins - 2:45AM204.2 ft. MWL - Water Level, 5 %of cross sectional area204.2 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (1)

  • General Observation - 15" VCP

    8 ft. - General Observation - 15" VCP

Observations (33)

DistanceCodeObservation
191.3TFOpen
167.9TFOpen
133.4FLH
21.9FLH
0MGOConn. @ Mh, 9 O' Clock. OPEN
126.7TFOpen
92.3FLH
67FLH
12.9FCHAIRLINE
178TFOpen
25.7FCH
0MGOConn. @ Mh, 3 O' Clock. OPEN
105.2FCH
0AMH2:45AM
78.7TFCCapped
36FCH
82.4FLH
189.8FCH
58.8FCSL
12.9FCSLIGHT
20.6FCSL
75.9TFOpen
0MWL
71.8FCH
89.9FLH
92.3FCH
204.2AMH3:10AM
79.4FLH
8MGO15" VCP
183.3TFOpen
122.1TFActive
146.2FCH
0MWM

Properties (6)

custom_field_three
FEW SLIGHT FRACTURES-HAIRLINES
custom_field_two
4
customer
LACSD
datetime
2018-08-27T01:49:46-07:00
documentation
MARTIN,REVELES,OLIVER 111
is_lateral_inspection
false