Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 27, 2018, 08:13 AM
  • 01 1134_01 1133_8272018_012826.mp4

Date
08/27/2018
W/O
0723688
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00210
PipeID
P01986
Time
1:13 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0955
Sewer Name
01 HUNTINGTON PARK TRUNK
City
HUNTINGTON PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
04
Purpose
Routine Assessment
Project
20180827MDM_HUNTINGTON_PARK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
01 1134
Downstream MH
01 1133
Dir. of Survey
Downstream
Length Surveyed
191.7 ft.
Total Length
191.7 ft.
Structural Index
3
Structural Quick
3525
Structural Rating
25
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
25
Pipe schematic from manhole 01 1134 to 01 1133
MH: 01 1134MH: 01 1133downstream0 ft. AMH - Upstream Manhole, Survey Begins - 1:25AM0 ft. MWL - Water Level, 0 %of cross sectional area - NO FLOW0 ft. MWM - Water Mark, 40 %of cross sectional area9 ft. MGO - General Observation - 15" VCP27.6 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - HAIRLINE66.3 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - HAIRLINE71.4 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H73.4 ft. FC - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES - H77.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active78.7 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - SLIGHT81.4 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H82.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open90 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active139.7 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H157.4 ft. FC - Fracture Circumferential, from 11 to 02 o'clock, within 8 inches of joint: YES - H160.6 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL176.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open178.4 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H186.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active191.1 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active191.7 ft. AMH - Downstream Manhole, Survey Ends - 1:45AM

Observation photos (1)

  • General Observation - 15" VCP

    9 ft. - General Observation - 15" VCP

Observations (21)

DistanceCodeObservation
139.7FLH
73.4FCH
191.1MGOConn. @ Mh, 9 O' Clock. Active
157.4FCH
90TFActive
66.3FLHAIRLINE
27.6FLHAIRLINE
71.4FLH
186.2TFActive
0AMH1:25AM
77.4TFActive
82.1TFOpen
160.6FCSL
178.4FCH
81.4FLH
191.7AMH1:45AM
0MWLNO FLOW
0MWM
176.6TFOpen
9MGO15" VCP
78.7FCSLIGHT

Properties (6)

custom_field_three
SLIGHT FRACTURE-HAIRLINES
custom_field_two
4
customer
LACSD
datetime
2018-08-27T01:13:07-07:00
documentation
MARTIN,REVELES,OLIVER 111
is_lateral_inspection
false