Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 22, 2018, 12:26 PM
  • 18 0853_18 0852_8222018_053216.mp4

Date
08/22/2018
W/O
0724790
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00709
PipeID
P14708
Time
5:26 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7791
Sewer Name
18 SO WHITTIER OUTFALL RLF TR, SECTS 1,2A,2B,2C,&3
City
NORWALK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
34
Purpose
Maintenance Related
Project
20180822SHO_SO_WHITTIER_OUTFALL_RELIEF_TRUNK_SECTS_1_2A_2B_2C_3
Material
Reinforced Concrete Pipe
Shape
Circular
Height
51 in.
Upstream MH
18 0852
Downstream MH
18 0853
Dir. of Survey
Upstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
4
Structural Quick
5131
Structural Rating
8
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
12
Pipe schematic from manhole 18 0852 to 18 0853
MH: 18 0852MH: 18 0853upstream0 ft. MSA - Survey Abandoned - VIEW OF THE UPLEG0 ft. SAP - Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES0 ft. SRC - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO0 ft. MGP - General Photograph2 ft. MWM - Water Mark, 60 %of cross sectional area2 ft. AMH - Downstream Manhole, Survey Begins - MH 8522 ft. MWL - Water Level, 40 %of cross sectional area

Observation photos (4)

  • Survey Abandoned - VIEW OF THE UPLEG

    2 ft. - Survey Abandoned - VIEW OF THE UPLEG

  • Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO

    2 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO

  • General Photograph

    2 ft. - General Photograph

Observations (7)

DistanceCodeObservation
2MSAVIEW OF THE UPLEG
0MWM
0AMHMH 852
2SAP
2SRC
0MWL
2MGP

Properties (7)

additional_info
LOOKING @ THE UPLEG OF THE SIPHON FOR ANY HOLES/MISSING WALL
custom_field_three
CORRODED REBAR
custom_field_two
2
customer
LACSD
datetime
2018-08-22T05:26:21-07:00
documentation
OBREGON, BRAR, VENDRYES, PARAISO
is_lateral_inspection
false