Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 20, 2018, 10:51 AM
  • 01 1113_01 1112_8202018_044814.mp4

Date
08/20/2018
W/O
0723688
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00210
PipeID
P01964
Time
3:51 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0953
Sewer Name
01 HUNTINGTON PARK TRUNK
City
HUNTING PARK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
04
Purpose
Routine Assessment
Project
20180820MDM_HUNTINGTON_PARK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
01 1113
Downstream MH
01 1112
Dir. of Survey
Downstream
Length Surveyed
397.8 ft.
Total Length
397.8 ft.
Structural Index
3
Structural Quick
3925
Structural Rating
37
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
43
Pipe schematic from manhole 01 1113 to 01 1112
MH: 01 1113MH: 01 1112downstream0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:50AM8 ft. MGO - General Observation - 18" VCP11.2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start32.5 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open34.2 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - HAIRLINE36 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped51.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open60.3 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H70 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active73.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped83.8 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - H100.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open113.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped128.5 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - LIGHTLY PEELING136.5 ft. TBI - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 2" - Open139.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped143.5 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H153.6 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H158.7 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - SL160 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open163.8 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H164.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped191.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open203.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open206 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - H208.4 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H218.4 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H235.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open240.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped253 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active253.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open258.4 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped298.8 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - SL304.9 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open305.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open305.2 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - H330 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H341.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open357.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped390.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped397.5 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active397.8 ft. AMH - Downstream Manhole, Survey Ends - 5:35AM

Observation photos (3)

  • General Observation - 18" VCP

    8 ft. - General Observation - 18" VCP

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    11.2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 2" - Open

    136.5 ft. - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 2" - Open

Observations (45)

DistanceCodeObservation
113.1TFCCapped
0MGOConn. @ Mh, 9 O' Clock. Active
330FLH
253.2TFOpen
160TBOpen
203.2TBOpen
8MGO18" VCP
240.6TFCCapped
357.2TFCCapped
143.5FCH
390.7TFCCapped
206FCH
218.4FLH
100.4TFOpen
11.2SSS
258.4TFCCapped
136.5TBIOpen
32.5TBOpen
397.5MGOConn. @ Mh, 9 O' Clock. Active
60.3FLH
153.6FLH
128.5SSSLIGHTLY PEELING
139.3TFCCapped
0MWM
0MWL
341.4TFOpen
235.5TFOpen
73.9TFCCapped
158.7FLSL
70TBActive
305.2TFOpen
0AMH4:50AM
51.2TFOpen
83.8FLH
36TFCCapped
397.8AMH5:35AM
163.8FLH
305.2FCH
191.3TFOpen
34.2FLHAIRLINE
298.8FLSL
253TBActive
164.7TFCCapped
208.4FCH
304.9TFOpen

Properties (6)

custom_field_three
SLIGHT & HAIRLINE FRACTURES
custom_field_two
4
customer
LACSD
datetime
2018-08-20T03:51:04-07:00
documentation
MARTIN,REVELES,OLIVER 111,YOUNG
is_lateral_inspection
false