Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 24, 2018, 07:20 AM
  • 01 1110_01 1109_8242018_021249.mp4

Date
08/24/2018
W/O
0723688
Weather
Dry
Operator/Surveyor
Oliver III
Sewer ID
Z00210
PipeID
P01960
Time
12:20 AM
Certificate
U-415-06024036
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0953
Sewer Name
01 HUNTINGTON PARK TRUNK
City
HUNTINGTON PARK TRUNK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
07
Purpose
Routine Assessment
Project
08242018ROIII_Huntington_Park_Trunk
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
01 1110
Downstream MH
01 1109
Dir. of Survey
Downstream
Length Surveyed
303.4 ft.
Total Length
303.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 01 1110 to 01 1109
MH: 01 1110MH: 01 1109downstream0 ft. AMH - Upstream Manhole, Survey Begins - 2:10am0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 05 o'clock, , within 8 inches of joint: YES, Start62 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - Open113.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4", 4" - Capped115.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 4" - Open128 ft. MWL - Water Level, 10 %of cross sectional area167.2 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 4" - Open214 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - Open265.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - Active299.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 08 o'clock, , within 8 inches of joint: YES, Finish299.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 05 o'clock, , within 8 inches of joint: YES, Finish303.4 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 8", 8" - Conn. @ Mh, 9 O' Clock. Active303.4 ft. AMH - Downstream Manhole, Survey Ends - 2:42am

Observations (16)

DistanceCodeObservation
128MWL
115.5TBOpen
299.8DAGS
0AMH2:10am
62TFOpen
0MWM
0MWL
265.4TFActive
2DAGS
2DAGS
167.2TFOpen
303.4TFAConn. @ Mh, 9 O' Clock. Active
299.8DAGS
113.1TFCCapped
214TFOpen
303.4AMH2:42am

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2018-08-24T00:20:47-07:00
documentation
Reveles, Oliver III
is_lateral_inspection
false