Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 26, 2018, 10:52 AM
  • 16 0321_16 0320_9262018_035640.mp4

Date
09/26/2018
W/O
0729304
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00665
PipeID
P13372
Time
3:52 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0983
Sewer Name
16 SAN MARINO OUTFALL TRUNK
City
SAN MARINO
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
17
Purpose
Capital Improvement Program Assesment
Project
20180921MDM_SAN_MARINO_OUTFALL_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
16 0321
Downstream MH
16 0320
Dir. of Survey
Downstream
Length Surveyed
226.9 ft.
Total Length
226.9 ft.
Structural Index
2
Structural Quick
3329
Structural Rating
27
O&M Index
2
O&M Quick
3121
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
33
Pipe schematic from manhole 16 0321 to 16 0320
MH: 16 0321MH: 16 0320downstream0 ft. AMH - Upstream Manhole, Survey Begins - 3:50AM0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Capped6.2 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - HAIRLINE11.3 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SLIGHT22 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SL24.1 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H32.1 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SL34.8 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H34.8 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SL42.3 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H45.3 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS45.3 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS45.3 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS45.3 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS72.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open74.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped96.9 ft. RFJ - Roots Fine Joint, at 09 o'clock, within 8 inches of joint: YESR - 2%113.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open118.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open154.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped171.9 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - 90% ROOTS-ACTIVE171.9 ft. RML - Roots Medium Lateral, from 02 to 03 o'clock, 5 %, within 8 inches of joint: YES223.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open226.3 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Finish - 10% HAIRLINE AT JOINTS226.3 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Finish - 10% SLIGHT AT JOINTS226.3 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 30% SLIGHT AT JOINTS226.3 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 30% HAIRLINE AT JOINTS226.3 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active226.9 ft. AMH - Downstream Manhole, Survey Ends - 4:25AM

Observations (30)

DistanceCodeObservation
118.6TFOpen
11.3FCSLIGHT
45.3FLHAIRLINE AT JOINTS
45.3FLSLIGHT AT JOINTS
113.5TFOpen
42.3FCH
171.9TFD90% ROOTS-ACTIVE
6.2FCHAIRLINE
0AMH3:50AM
0MGOConn. @ Mh, 9 O' Clock. Capped
226.3FL10% HAIRLINE AT JOINTS
34.8FCH
34.8FCSL
226.3FL10% SLIGHT AT JOINTS
45.3FCHAIRLINE AT JOINTS
96.9RFJ2%
32.1FCSL
171.9RML
72.1TFOpen
74.3TFCCapped
24.1FLH
226.3FC30% SLIGHT AT JOINTS
223.5TFOpen
22FCSL
45.3FCSLIGHT AT JOINTS
226.9AMH4:25AM
226.3FC30% HAIRLINE AT JOINTS
226.3MGOConn. @ Mh, 9 O' Clock. Active
0MGOConn. @ Mh, 3 O' Clock. Capped
154.3TFCCapped

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2018-09-26T03:52:25-07:00
documentation
MARTIN,REVELES,OLIVER 111,BRAR
is_lateral_inspection
false