Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 26, 2018, 09:58 AM
  • 16 0322_16 0321_9262018_034201.mp4

Date
09/26/2018
W/O
0729304
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00665
PipeID
P13373
Time
2:58 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0983
Sewer Name
16 SAN MARINO OUTFALL TRUNK
City
SAN MARINO
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
17
Purpose
Capital Improvement Program Assesment
Project
20180921MDM_SAN_MARINO_OUTFALL_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
16 0322
Downstream MH
16 0321
Dir. of Survey
Downstream
Length Surveyed
61.8 ft.
Total Length
61.8 ft.
Structural Index
2
Structural Quick
2700
Structural Rating
14
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
16
Pipe schematic from manhole 16 0322 to 16 0321
MH: 16 0322MH: 16 0321downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:30AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active10.3 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open-80% ROOTS12.2 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - HAIRLINE14.2 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SLIGHT24.7 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H25.7 ft. MGO - General Observation - 15" VCP32.5 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - SL32.5 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SL35 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SL40 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - H58.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped61.2 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Capped61.2 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped61.8 ft. AMH - Downstream Manhole, Survey Ends - 3:40AM

Observation photos (1)

  • General Observation - 15" VCP

    25.7 ft. - General Observation - 15" VCP

Observations (17)

DistanceCodeObservation
32.5FCSL
0MWM
35FCSL
0AMH3:30AM
61.2MGOConn. @ Mh, 3 O' Clock. Capped
58.8TFCCapped
0MWL
24.7FCH
61.8AMH3:40AM
0MGOConn. @ Mh, 9 O' Clock. Active
12.2FCHAIRLINE
10.3TFDOpen-80% ROOTS
61.2MGOConn. @ Mh, 9 O' Clock. Capped
14.2FCSLIGHT
32.5FCSL
40FCH
25.7MGO15" VCP

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2018-09-26T02:58:09-07:00
documentation
MARTIN,REVELES,OLIVER 111,BRAR
is_lateral_inspection
false