Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 21, 2018, 06:06 PM
  • A 0575_H 0403_9212018_124122.mp4

Date
09/21/2018
W/O
0729413
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00177
PipeID
P10833
Time
11:06 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7815
Sewer Name
H JOINT OUTFALL H - UNIT 5A
City
INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
01
Purpose
Capital Improvement Program Assesment
Project
20180920DF_JOINT_OUTFALL_H_UNIT_5A
Material
Reinforced Concrete Pipe
Shape
Circular
Height
60 in.
Upstream MH
A 0575
Downstream MH
H 0403
Dir. of Survey
Downstream
Length Surveyed
15 ft.
Total Length
15 ft.
Structural Index
4
Structural Quick
5132
Structural Rating
11
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
11
Pipe schematic from manhole A 0575 to H 0403
MH: A 0575MH: H 0403downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:40 PM0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 65% MAG2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start12 ft. MGP - General Photograph12 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 65% MAG12 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish12 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish12 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish13.3 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active14 ft. MGO - General Observation - GREASE THROUGHOUT THE REACH (5%)14 ft. MGO - General Observation - Peeling & Flaking Throughout The Reach15 ft. AMH - Downstream Manhole, Survey Ends - 12:49 PM

Observation photos (5)

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 65% MAG

    2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 65% MAG

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    12 ft. - General Photograph

Observations (16)

DistanceCodeObservation
2SRV
0MWL
14MGOGREASE THROUGHOUT THE REACH (5%)
0AMH12:40 PM
12MGP
2SAP
15AMH12:49 PM
2SZ65% MAG
12SZ65% MAG
0MWM
13.3MGOConn. @ Mh, 9 O' Clock. Active
12SRV
14MGOPeeling & Flaking Throughout The Reach
12SAP
2SAV
12SAV

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2018-09-21T11:06:32-07:00
documentation
FRANKLIN, IGNACIO, PARAISO, VENDRYES
is_lateral_inspection
false