Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 24, 2018, 06:04 PM
  • E 0109_E 0108_9242018_110901.mp4

Date
09/24/2018
W/O
0730604
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00032
PipeID
P11335
Time
11:04 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7816
Sewer Name
E JOINT OUTFALL E - UNIT 5
City
LOS ANGELES
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Routine Assessment
Project
20180920DF_JOINT_OUTFALL_E_UNIT_5
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Upstream MH
E 0109
Downstream MH
E 0108
Dir. of Survey
Downstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
5132
Structural Rating
13
O&M Index
5
O&M Quick
5141
O&M Rating
9
Overall Index
4
Overall Quick
Overall Rating
22
Pipe schematic from manhole E 0109 to E 0108
MH: E 0109MH: E 0108downstream0 ft. MWM - Water Mark, 100 %of cross sectional area0 ft. MWL - Water Level, 100 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 11:07 AM1.8 ft. MGP - General Photograph - AIRLINE2 ft. MGO - General Observation - Peeling & Flaking Throughout The Reach2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES2 ft. MGO - General Observation - ROACHES2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES2 ft. MGP - General Photograph2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES - 70% MAG2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES2 ft. MGO - General Observation - GREASE THROUGHOUT THE REACH (5%)2 ft. LU - Alignment Up, 45 %2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES2.1 ft. MSA - Survey Abandoned - 11:14 AM

Observation photos (10)

  • Water Level, 100 %of cross sectional area

    0 ft. - Water Level, 100 %of cross sectional area

  • General Photograph - AIRLINE

    1.8 ft. - General Photograph - AIRLINE

  • General Observation - Peeling & Flaking Throughout The Reach

    2 ft. - General Observation - Peeling & Flaking Throughout The Reach

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

  • General Observation - ROACHES

    2 ft. - General Observation - ROACHES

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

  • General Photograph

    2 ft. - General Photograph

  • Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES - 70% MAG

    2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES - 70% MAG

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
1.8MGPAIRLINE
2MGOPeeling & Flaking Throughout The Reach
2.1MSA11:14 AM
2SSS
2MGOROACHES
2SRV
2MGP
2SZ70% MAG
2SAP
2MGOGREASE THROUGHOUT THE REACH (5%)
0MWM
0MWL
2LU
2SAV
0AMH11:07 AM

Properties (6)

additional_info
VIEW OF THE DOWNLEG FROM THE U/S SIPHON
custom_field_two
5
customer
LACSD
datetime
2018-09-24T11:04:30-07:00
documentation
FRANKLIN, VENDRYES, PARAISO, YOUNG
is_lateral_inspection
false