Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 1, 2018, 08:45 AM
  • 02 2201_02 2200_1012018_015220.mp4

Date
10/01/2018
W/O
0731794
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00253
PipeID
P04474
Time
1:45 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0991
Sewer Name
02 DOWNEY-BELLFLOWER DIVERSION RELIEF TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
30
Purpose
Routine Assessment
Project
2080928MDM_DOWNEY_BELLFLOWER_DIVERSION_RELIEF_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
02 2201
Downstream MH
02 2200
Dir. of Survey
Downstream
Length Surveyed
566.6 ft.
Total Length
566.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 02 2201 to 02 2200
MH: 02 2201MH: 02 2200downstream0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:45AM8 ft. MGO - General Observation - 21" VCP492.3 ft. DSGV - Deposits Settled Gravel, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start501.4 ft. DSGV - Deposits Settled Gravel, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish566.6 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active566.6 ft. AMH - Downstream Manhole, Survey Ends - 2:15AM

Observation photos (1)

  • General Observation - 21" VCP

    8 ft. - General Observation - 21" VCP

Observations (9)

DistanceCodeObservation
0MGOConn. @ Mh, 3 O' Clock. Active
501.4DSGV
0MWM
566.6MGOConn. @ Mh, 3 O' Clock. Active
8MGO21" VCP
566.6AMH2:15AM
0MWL
492.3DSGV
0AMH1:45AM

Properties (4)

custom_field_two
4
customer
LACSD
datetime
2018-10-01T01:45:00-07:00
is_lateral_inspection