- Date
- 09/27/2018
- W/O
- 0731413
- Weather
- Dry
- Operator/Surveyor
- FRANKLIN
- Sewer ID
- Z00323
- PipeID
- P08117
- Time
- 10:21 AM
- Certificate
- U-415-06024039
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7820
- Sewer Name
- A JOA-1A LOS COYOTES WRP INTERCEPTOR
- City
- BELLFLOWER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 32
- Purpose
- Routine Assessment
- Project
- 20180927DF_JOA_1A_LOS_COYOTES_WRP_INTERCEPTOR
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 78 in.
- Upstream MH
- A 0181
- Downstream MH
- A 0180
- Dir. of Survey
- Downstream
- Length Surveyed
- 987.6 ft.
- Total Length
- 987.6 ft.
- Structural Index
- 3
- Structural Quick
- 5131
- Structural Rating
- 10
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 10
Pipe schematic from manhole A 0181 to A 0180 Observation photos (8)

2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 75% MAG

2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

47.9 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

162.5 ft. - General Photograph

364 ft. - General Photograph

552 ft. - General Photograph

791.8 ft. - General Photograph