Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 8, 2017, 07:24 AM
  • C 0682_C 0112 _09082017_002543.mp4

Date
09/08/2017
W/O
651656
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00126
PipeID
P24965
Time
12:24 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4962
Sewer Name
C JOINT OUTFALL C - UNIT 4A
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
24
Purpose
Routine Assessment
Project
WO_651656_TV03070_AUG2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
C 0682
Downstream MH
C 0112
Dir. of Survey
Downstream
Length Surveyed
26.3 ft.
Total Length
26.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4221
O&M Rating
10
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole C 0682 to C 0112
MH: C 0682MH: C 0112downstream0 ft. MWL - Water Level, 50 %of cross sectional area0 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 06822.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 09 to 09 o'clock, , within 8 inches of joint: YES, Start15.3 ft. MCU - Camera Underwater, Start26.3 ft. MSA - Survey Abandoned - WATER LEVEL26.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 09 to 09 o'clock, , within 8 inches of joint: YES, Finish26.3 ft. MCU - Camera Underwater, Finish

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 09 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 09 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
15.3MCU
2.9DAGS
0MWL
26.3MSAWATER LEVEL
0MWM
26.3DAGS
0AMHC 0682
26.3MCU

Properties (5)

additional_info
SC345953
custom_field_two
5
customer
LACSD
datetime
2017-09-08T00:24:46-07:00
is_lateral_inspection
false