Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 26, 2018, 04:05 PM
  • 02 2321_02 2320_4262018_100736.mp4

Date
04/26/2018
W/O
0695764
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00271
PipeID
P04111
Time
9:05 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7693
Sewer Name
02 INDIANA STREET TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
11A
Purpose
Routine Assessment
Project
20180426DF_INDIANA_STREET_TRUNK
Material
NRCP
Shape
Circular
Height
7.519999980926514 in.
Upstream MH
02 2321
Downstream MH
02 2320
Dir. of Survey
Downstream
Length Surveyed
188.8 ft.
Total Length
188.8 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 02 2321 to 02 2320
MH: 02 2321MH: 02 2320downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 9:08 AM0.1 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start55.1 ft. MGP - General Photograph84.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4" - Open151 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4"153.1 ft. MGP - General Photograph153.3 ft. MGP - General Photograph - REPAIR @ 12 O'CLOCK187.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish187.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish188 ft. MGO - General Observation - ROACHES @ MH188.8 ft. MGO - General Observation - Grease Throughout The Reach (5%)188.8 ft. AMH - Downstream Manhole, Survey Ends - 11:00 AM

Observation photos (4)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    55.1 ft. - General Photograph

  • General Photograph

    153.1 ft. - General Photograph

  • General Photograph - REPAIR @ 12 O'CLOCK

    153.3 ft. - General Photograph - REPAIR @ 12 O'CLOCK

Observations (15)

DistanceCodeObservation
187.8SSS
151TFA
84.1TFOpen
153.1MGP
0.1MWM
188.8MGOGrease Throughout The Reach (5%)
0MWL
153.3MGPREPAIR @ 12 O'CLOCK
0AMH9:08 AM
2CM
187.8CM
188MGOROACHES @ MH
188.8AMH11:00 AM
55.1MGP
2SSS

Properties (7)

additional_info
CORRECT TAPE NUMBER IS G7693
custom_field_two
3
customer
LACSD
datetime
2018-04-26T09:05:59-07:00
is_lateral_inspection
false
lining
CIPP
year_laid
20060517