Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 30, 2018, 04:19 PM
  • 05 0347_05 1180_7302018_093723.mp4

Date
07/30/2018
W/O
0717904
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00514
PipeID
P06419
Time
9:19 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7771
Sewer Name
05 ROSECRANS AVENUE TRUNK
City
HAWTHORNE
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
17
Purpose
Routine Assessment
Project
20180730SHO_ROSECRANS_AVENUE_TRUNK
Material
NRCP
Shape
Circular
Height
11.300000190734863 in.
Upstream MH
05 1180
Downstream MH
05 0347
Dir. of Survey
Upstream
Length Surveyed
309.2 ft.
Total Length
309.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
3123
O&M Rating
9
Overall Index
2
Overall Quick
Overall Rating
9
Pipe schematic from manhole 05 1180 to 05 0347
MH: 05 1180MH: 05 0347upstream0 ft. AMH - Upstream Manhole, Survey Ends - MH 034747.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"68.6 ft. MGO - General Observation - LOOSE LINER TAPE102.5 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"148 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"156.1 ft. MGO - General Observation - LOOSE LINER TAPE196 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6"196 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO, Finish - DEBRIS228.1 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO, Start - DEBRIS247 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"294.6 ft. TBD - Tap Break-In Defective, at 10 o'clock, -, , within 8 inches of joint: NO, 6"297.6 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6"309.2 ft. AMH - Downstream Manhole, Survey Begins - MH 1180309.2 ft. MWM - Water Mark, 15 %of cross sectional area309.2 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (3)

  • Tap Break-In Defective, at 10 o'clock, -,  , within 8 inches of joint: NO, 6"

    14.6 ft. - Tap Break-In Defective, at 10 o'clock, -, , within 8 inches of joint: NO, 6"

  • General Observation - LOOSE LINER TAPE

    153.1 ft. - General Observation - LOOSE LINER TAPE

  • General Observation - LOOSE LINER TAPE

    240.6 ft. - General Observation - LOOSE LINER TAPE

Observations (15)

DistanceCodeObservation
113.2TFD
153.1MGOLOOSE LINER TAPE
11.6TFD
240.6MGOLOOSE LINER TAPE
0AMHMH 1180
262TFC
14.6TBD
81.1DSZDEBRIS
113.2DSZDEBRIS
62.2TF
0MWM
0MWL
309.2AMHMH 0347
206.7TF
161.2TF

Properties (8)

custom_field_three
LINER IS IN GOOD CONDTION
custom_field_two
4
customer
LACSD
datetime
2018-07-30T09:19:28-07:00
documentation
OBREGON, BRAR, PARAISO
is_lateral_inspection
false
lining
CIPP
year_laid
20050531