Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 18, 2018, 12:12 PM
  • J 0400_J 0352_1182018_041537.mp4

  • J 0400_J 0352_1182018_060100.mp4

Date
01/18/2018
W/O
#
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00070
PipeID
P21091
Time
4:12 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0728
Sewer Name
J JOINT OUTFALL J - UNIT 5C
City
PALOS VERDES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
07
Purpose
Routine Assessment
Project
20180118MDM_JOINT_OUTFALL_J_UNIT_5C
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
J 0400
Downstream MH
J 0352
Dir. of Survey
Downstream
Length Surveyed
234.7 ft.
Total Length
234.7 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
2
O&M Quick
2212
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
8
Pipe schematic from manhole J 0400 to J 0352
MH: J 0400MH: J 0352downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:10AM6.5 ft. RFJ - Roots Fine Joint, from 04 to 05 o'clock, within 8 inches of joint: YESR - 3%25 ft. FC - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES - SLIGHT25.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open36.4 ft. MGO - General Observation - 15" VCP49.4 ft. RFJ - Roots Fine Joint, from 07 to 10 o'clock, within 8 inches of joint: YESR - 4%140.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open160.3 ft. DSGV - Deposits Settled Gravel, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES165.2 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES - ROCK165.9 ft. MGO - General Observation - CCTV LARGE WHEELS ON TRACTOR177 ft. MWL - Water Level, 30 %of cross sectional area216.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 65" - Open234.7 ft. AMH - Downstream Manhole, Survey Ends - 6:00AM

Observation photos (1)

  • General Observation - 15" VCP

    36.4 ft. - General Observation - 15" VCP

Observations (15)

DistanceCodeObservation
0MWL
177MWL
216.8TFOpen
165.2DSZROCK
0MWM
6.5RFJ3%
160.3DSGV
140.7TFOpen
36.4MGO15" VCP
49.4RFJ4%
25.9TFOpen
165.9MGOCCTV LARGE WHEELS ON TRACTOR
25FCSLIGHT
234.7AMH6:00AM
0AMH4:10AM

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2018-01-18T04:12:44-08:00
documentation
MARTIN,MANANES,REVELES
is_lateral_inspection
false