Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 17, 2018, 12:45 PM
  • 19 0215_19 0214_1172018_050423.mp4

Date
01/17/2018
W/O
#
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00718
PipeID
P15184
Time
4:45 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0726
Sewer Name
19 ARTESIA-CERRITOS TRUNK
City
ARTESIA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Routine Assessment
Project
20180117MDM_ARTESIA_CERRITOS_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
19 0215
Downstream MH
19 0214
Dir. of Survey
Downstream
Length Surveyed
246.8 ft.
Total Length
246.8 ft.
Structural Index
3
Structural Quick
3A2A
Structural Rating
56
O&M Index
2
O&M Quick
4124
O&M Rating
12
Overall Index
3
Overall Quick
Overall Rating
68
Pipe schematic from manhole 19 0215 to 19 0214
MH: 19 0215MH: 19 0214downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 5:05AM-( ABANDONED MH)0 ft. MWL - Water Level, 10 %of cross sectional area8.6 ft. MGO - General Observation - 12" VCP21.7 ft. DAR - Deposits Attached Ragging, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES30.6 ft. DAR - Deposits Attached Ragging, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES35.4 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SLIGHT35.4 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - SLIGHT52.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped70.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped81.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 04 o'clock, , within 8 inches of joint: NO81.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open100.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped102.4 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - HAIRLINE102.4 ft. MWL - Water Level, 40 %of cross sectional area102.4 ft. FL - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES - H110.4 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H110.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H122.3 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H130.4 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H138.5 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H146.6 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H147.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open149.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped151.6 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES151.6 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SL152.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open182.7 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - SL182.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL186.7 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H186.7 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H202.9 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H203.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped217.8 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - SL221.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL221.5 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H221.5 ft. MWM - Water Mark, 30 %of cross sectional area226.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL229.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H242.2 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL246.3 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active246.8 ft. AMH - Downstream Manhole, Survey Ends - 5:35AM

Observation photos (1)

  • Upstream Manhole, Survey Begins - 5:05AM-( ABANDONED MH)

    0 ft. - Upstream Manhole, Survey Begins - 5:05AM-( ABANDONED MH)

Observations (42)

DistanceCodeObservation
35.4FCSLIGHT
186.7FCH
110.4FCH
102.4FCHAIRLINE
70.9TFCCapped
130.4FLH
81.9DAGS
0MWM
186.7FLH
122.3FLH
110.4FLH
52.3TFCCapped
226.8FLSL
35.4FCSLIGHT
202.9FCH
246.3MGOConn. @ Mh, 9 O' Clock. Active
246.8AMH5:35AM
217.8FCSL
182.7FLSL
146.6FLH
149.9TFCCapped
242.2FCSL
8.6MGO12" VCP
100.4TFCCapped
102.4MWL
102.4FLH
203.8TFCCapped
30.6DAR
152.5TFOpen
138.5FLH
221.5FLSL
0AMH5:05AM-( ABANDONED MH)
229.8FLH
21.7DAR
221.5FCH
151.6DAGS
81.9TFOpen
182.7FLSL
221.5MWM
147.7TFOpen
151.6FCSL
0MWL

Properties (6)

custom_field_three
HAIRLINE & SLIGHT FRACTURES
custom_field_two
4
customer
LACSD
datetime
2018-01-17T04:45:21-08:00
documentation
MARTIN,MANANES,OLIVER 111
is_lateral_inspection