Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 13, 2018, 01:45 PM
  • Section#1_H 0116_H 0115__1132018__G6917.mp4

Date
01/13/2018
W/O
0683963
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00165
PipeID
P10567
Time
5:45 AM
Certificate
U-101406022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6917
Sewer Name
H JOINT OUTFALL H - UNIT 1F
City
HUNTINGTON PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
04
Purpose
Capital Improvement Program Assesment
Project
20180113MDM_JOINT_OUTFALL_H_UNIT_1F
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Upstream MH
H 0116
Downstream MH
H 0115
Dir. of Survey
Downstream
Length Surveyed
444.6 ft.
Total Length
444.6 ft.
Structural Index
2
Structural Quick
2L00
Structural Rating
128
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
128
Pipe schematic from manhole H 0116 to H 0115
MH: H 0116MH: H 0115downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 5:45AM2.1 ft. MGO - General Observation - MAG COAT 95% START 8:00 TO 4:002.1 ft. MGO - General Observation - THICK MAG COAT53.1 ft. SSS - Surface Spalling, at 01 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT91.2 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT100.3 ft. SSS - Surface Spalling, from 09 to 10 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT137.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING BLISTERING CONCRETE UNDER MAG COAT444.1 ft. MGO - General Observation - MAG COAT 95% FINISH444.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - FLAKING BLISTERING CONCRETE UNDER MA COAT444.6 ft. AMH - Downstream Manhole, Survey Ends - 6:30AM

Observation photos (6)

  • General Observation - MAG COAT 95% START 8:00 TO 4:00

    2.1 ft. - General Observation - MAG COAT 95% START 8:00 TO 4:00

  • General Observation - THICK MAG COAT

    2.1 ft. - General Observation - THICK MAG COAT

  • Surface Spalling, at 01 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT

    53.1 ft. - Surface Spalling, at 01 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT

  • Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT

    91.2 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT

  • Surface Spalling, from 09 to 10 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT

    100.3 ft. - Surface Spalling, from 09 to 10 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING BLISTERING CONCRETE UNDER MAG COAT

    137.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING BLISTERING CONCRETE UNDER MAG COAT

Observations (12)

DistanceCodeObservation
0MWL
444.6AMH6:30AM
444.1MGOMAG COAT 95% FINISH
100.3SSSBLISTERING CONCRETE UNDER MAG COAT
91.2SSSBLISTERING CONCRETE UNDER MAG COAT
2.1MGOMAG COAT 95% START 8:00 TO 4:00
0MWM
53.1SSSBLISTERING CONCRETE UNDER MAG COAT
0AMH5:45AM
137.6SSSFLAKING BLISTERING CONCRETE UNDER MAG COAT
2.1MGOTHICK MAG COAT
444.1SSSFLAKING BLISTERING CONCRETE UNDER MA COAT

Properties (6)

custom_field_three
BLISTERING CONCRETE-95% MAG COAT
custom_field_two
3
customer
LACSD
datetime
2018-01-13T05:45:47-08:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false