Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 5, 2019, 05:53 PM
  • Section#1_29 0529A_29 0529__652019__I0153.mp4

Date
06/05/2019
W/O
0771885
Weather
Dry
Operator/Surveyor
BRAR
Sewer ID
Z01106
PipeID
P24584
Time
10:53 AM
Certificate
SEE REMARKS
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0153
Sewer Name
29 19TH STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Capital Improvement Program Assesment
Project
20190605SB_19TH_STREET_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0529
Downstream MH
29 0529A
Dir. of Survey
Upstream
Length Surveyed
244.3 ft.
Total Length
244.3 ft.
Structural Index
3
Structural Quick
3I2I
Structural Rating
240
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
243
Pipe schematic from manhole 29 0529 to 29 0529A
MH: 29 0529MH: 29 0529Aupstream0 ft. AMH - Upstream Manhole, Survey Ends - 244'0 ft. MGP - General Photograph0 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"8.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"34.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - OPEN47.4 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN51 ft. MGP - General Photograph54.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"82.3 ft. MGP - General Photograph101.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"117.1 ft. MGP - General Photograph138 ft. RFJ - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YESR - 5%144.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN171.9 ft. MGP - General Photograph185.4 ft. MGP - General Photograph197.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN200.8 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4" - 5% ROOTS IN LATERAL242.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start242.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start242.3 ft. MGP - General Photograph244.2 ft. MWM - Water Mark, 10 %of cross sectional area244.2 ft. MGO - General Observation - COCKROACHES IN MANHOLE244.2 ft. MWL - Water Level, 5 %of cross sectional area244.3 ft. AMH - Downstream Manhole, Survey Begins - 10:59 AM

Observation photos (17)

  • General Photograph

    2 ft. - General Photograph

  • Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4" - 5% ROOTS IN LATERAL

    43.5 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4" - 5% ROOTS IN LATERAL

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN

    46.4 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN

  • General Photograph

    58.9 ft. - General Photograph

  • General Photograph

    72.4 ft. - General Photograph

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN

    100.1 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN

  • Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YESR - 5%

    106.3 ft. - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YESR - 5%

  • General Photograph

    127.2 ft. - General Photograph

  • Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"

    143 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"

  • General Photograph

    162 ft. - General Photograph

  • Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"

    189.5 ft. - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"

  • General Photograph

    193.3 ft. - General Photograph

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN

    196.9 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - OPEN

    209.4 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - OPEN

  • Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"

    235.5 ft. - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"

  • Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"

    242.3 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"

  • General Photograph

    244.3 ft. - General Photograph

Observations (26)

DistanceCodeObservation
106.3RFJ5%
2SSS
196.9TBOPEN
46.4TFOPEN
244.3AMH244'
143TFA
244.3MGP
72.4MGP
209.4TFOPEN
0.1MWM
2CM
0.1MGOCOCKROACHES IN MANHOLE
43.5TFD5% ROOTS IN LATERAL
189.5TFA
2MGP
242.3TBA
58.9MGP
235.5TFA
0AMH10:59 AM
244.3CM
0.1MWL
162MGP
244.3SSS
193.3MGP
127.2MGP
100.1TFOPEN

Properties (6)

additional_info
U-0618-0703002249
custom_field_two
3
customer
LACSD
datetime
2019-06-05T10:53:43-07:00
documentation
BRAR, FRANKLIN, CASTILLO
is_lateral_inspection
false