Section#1_29 0529A_29 0529__652019__I0153.mp4
2 ft. - General Photograph
43.5 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4" - 5% ROOTS IN LATERAL
46.4 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN
58.9 ft. - General Photograph
72.4 ft. - General Photograph
100.1 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN
106.3 ft. - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YESR - 5%
127.2 ft. - General Photograph
143 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"
162 ft. - General Photograph
189.5 ft. - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"
193.3 ft. - General Photograph
196.9 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN
209.4 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - OPEN
235.5 ft. - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"
242.3 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"
244.3 ft. - General Photograph
| Distance | Code | Observation |
|---|---|---|
| 106.3 | RFJ | 5% |
| 2 | SSS | — |
| 196.9 | TB | OPEN |
| 46.4 | TF | OPEN |
| 244.3 | AMH | 244' |
| 143 | TFA | — |
| 244.3 | MGP | — |
| 72.4 | MGP | — |
| 209.4 | TF | OPEN |
| 0.1 | MWM | — |
| 2 | CM | — |
| 0.1 | MGO | COCKROACHES IN MANHOLE |
| 43.5 | TFD | 5% ROOTS IN LATERAL |
| 189.5 | TFA | — |
| 2 | MGP | — |
| 242.3 | TBA | — |
| 58.9 | MGP | — |
| 235.5 | TFA | — |
| 0 | AMH | 10:59 AM |
| 244.3 | CM | — |
| 0.1 | MWL | — |
| 162 | MGP | — |
| 244.3 | SSS | — |
| 193.3 | MGP | — |
| 127.2 | MGP | — |
| 100.1 | TF | OPEN |