Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 3, 2019, 08:05 AM
  • B 0451_B 0450_632019_012227.mp4

Date
06/03/2019
W/O
0772196
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00093
PipeID
P08963
Time
1:05 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1220
Sewer Name
B JOINT OUTFALL B - UNIT 5C
City
SIERRA MADRE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
11
Purpose
Capital Improvement Program Assesment
Project
20190603MDM_JOINT_OUTFALL_B_UNIT_5C
Material
NRCP
Shape
Circular
Height
21 in.
Upstream MH
B 0451
Downstream MH
B 0450
Dir. of Survey
Downstream
Length Surveyed
175.8 ft.
Total Length
175.8 ft.
Structural Index
3
Structural Quick
4322
Structural Rating
16
O&M Index
3
O&M Quick
3121
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
21
Pipe schematic from manhole B 0451 to B 0450
MH: B 0451MH: B 0450downstream0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. AMH - Upstream Manhole, Survey Begins - 1:10AM0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 4 O' Clock. Active2 ft. MGO - General Observation - MAG COAT 85% START2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED15.9 ft. SAM - Surface Aggregate Missing, from 02 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG71.8 ft. SSS - Surface Spalling, from 12 to 03 o'clock, within 8 inches of joint: NO - PELLING CONCRETE SEVERE AGG ATTACHED80.6 ft. RMJ - Roots Medium Joint, from 08 to 11 o'clock, 15 %, within 8 inches of joint: YESR80.6 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active-99% ROOTS84.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped150.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped153.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open159.7 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG175.3 ft. MGO - General Observation - 85% MAG COAT FINISH175.3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - PEELING CONCRETE SEVERE AGG ATTACHED175.3 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG175.8 ft. AMH - Downstream Manhole, Survey Ends - 1:35AM

Observation photos (7)

  • General Observation - MAG COAT 85% START

    2 ft. - General Observation - MAG COAT 85% START

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED

  • Surface Aggregate Missing, from 02 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

    15.9 ft. - Surface Aggregate Missing, from 02 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Spalling, from 12 to 03 o'clock, within 8 inches of joint: NO - PELLING CONCRETE SEVERE AGG ATTACHED

    71.8 ft. - Surface Spalling, from 12 to 03 o'clock, within 8 inches of joint: NO - PELLING CONCRETE SEVERE AGG ATTACHED

  • Roots Medium Joint, from 08 to 11 o'clock, 15 %, within 8 inches of joint: YESR

    80.6 ft. - Roots Medium Joint, from 08 to 11 o'clock, 15 %, within 8 inches of joint: YESR

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

    159.7 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

Observations (20)

DistanceCodeObservation
80.6RMJ
15.9SAMSEVERE AGG
2MGOMAG COAT 85% START
150.6TFCCapped
80.6TFDActive-99% ROOTS
175.8AMH1:35AM
0MGOConn. @ Mh, 3 O' Clock. Active
71.8SSSPELLING CONCRETE SEVERE AGG ATTACHED
0AMH1:10AM
175.3MGO85% MAG COAT FINISH
2SAMSEVERE AGG
175.3SSSPEELING CONCRETE SEVERE AGG ATTACHED
0MWM
175.3SAMSEVERE AGG
2SSSPEELING CONCRETE SEVERE AGG ATTACHED
0MWL
159.7SAMSEVERE AGG
153.8TFOpen
0MGOConn. @ Mh, 4 O' Clock. Active
84.9TFCCapped

Properties (6)

custom_field_three
PEELING CONCRETE SEVERE AGG ATTACHED-85% MAG COAT
custom_field_two
2
customer
LACSD
datetime
2019-06-03T01:05:02-07:00
documentation
MARTIN,REVELES,OLIVER 111
is_lateral_inspection
false