Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 22, 2019, 07:01 AM
  • 21 0987_21 0986 _03222019_001622.mp4

Date
03/22/2019
W/O
756623
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00784
PipeID
P16087
Time
12:01 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6490
Sewer Name
21 SAN ANTONIO TRUNK
City
POMONA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
09
Purpose
Routine Assessment
Project
WO_756623_TV21039_MAR2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
21 0987
Downstream MH
21 0986
Dir. of Survey
Downstream
Length Surveyed
278.4 ft.
Total Length
278.4 ft.
Structural Index
3
Structural Quick
3B00
Structural Rating
45
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
45
Pipe schematic from manhole 21 0987 to 21 0986
MH: 21 0987MH: 21 0986downstream0 ft. AMH - Upstream Manhole, Survey Begins - 21 09870 ft. MGO - General Observation - CONNECTION IN MH 3 OCLOCK0 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. MWL - Water Level, 40 %of cross sectional area3.8 ft. MGO - General Observation - MAG COAT THROUGHOUT PIPE202.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start275.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish275.6 ft. MGO - General Observation - MAG COAT THROUGHOUT PIPE278.4 ft. AMH - Downstream Manhole, Survey Ends - 21 0986

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    202.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
278.4AMH21 0986
275.5SAV
0AMH21 0987
275.6MGOMAG COAT THROUGHOUT PIPE
0MGOCONNECTION IN MH 3 OCLOCK
202.1SAV
3.8MGOMAG COAT THROUGHOUT PIPE
0MWM
0MWL

Properties (4)

customer
LACSD
datetime
2019-03-22T00:01:50-07:00
documentation
PROPIPE
is_lateral_inspection
false