Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 21, 2019, 07:13 AM
  • 18 0421_18 0420 _03212019_002451.mp4

Date
03/21/2019
W/O
756105
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00699
PipeID
P14256
Time
12:13 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6488
Sewer Name
18 SANTA FE STREET RELIEF TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_756105_TV18189_MAR2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0421
Downstream MH
18 0420
Dir. of Survey
Downstream
Length Surveyed
154 ft.
Total Length
154 ft.
Structural Index
3
Structural Quick
3E00
Structural Rating
87
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
92
Pipe schematic from manhole 18 0421 to 18 0420
MH: 18 0421MH: 18 0420downstream0 ft. MWM - Water Mark, 75 %of cross sectional area0 ft. MWL - Water Level, 60 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 04215.5 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start61.1 ft. MGO - General Observation - MAG COAT THROUGHOUT PIPE151.2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish154 ft. AMH - Downstream Manhole, Survey Ends - 18 0420

Observation photos (2)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    5.5 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COAT THROUGHOUT PIPE

    61.1 ft. - General Observation - MAG COAT THROUGHOUT PIPE

Observations (7)

DistanceCodeObservation
5.5SAP
0MWM
151.2SAP
0MWL
61.1MGOMAG COAT THROUGHOUT PIPE
154AMH18 0420
0AMH18 0421

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-03-21T00:13:26-07:00
documentation
PROPIPE
is_lateral_inspection
false