21 1088_21 1087 _03262019_005525.mp4
2.5 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start
2.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start
19.2 ft. - Fracture Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES
23.1 ft. - Fracture Multiple, from 11 to 05 o'clock, within 8 inches of joint: YES, Start
55.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
115.9 ft. - Fracture Multiple, from 02 to 05 o'clock, within 8 inches of joint: YES
176.7 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES
229.6 ft. - Fracture Multiple, from 09 to 05 o'clock, within 8 inches of joint: YES
273.8 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES
310.4 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 2.5 | SAP | — |
| 366.8 | DAGS | — |
| 315.9 | TFC | — |
| 291.4 | TFC | — |
| 19.2 | FM | — |
| 51.1 | FM | — |
| 368.4 | AMH | 21 1087 |
| 360.4 | TFC | — |
| 115.9 | FM | — |
| 238.8 | TFC | — |
| 23.1 | FM | — |
| 273.8 | FM | — |
| 0 | AMH | 21 1088 |
| 267 | TF | — |
| 55.3 | FM | — |
| 85 | TFC | — |
| 2.5 | DAGS | — |
| 0 | MWM | — |
| 121.5 | TFC | — |
| 0 | MWL | — |
| 28.6 | TFC | — |
| 229.6 | FM | — |
| 366.8 | SAP | — |
| 87.3 | FM | — |
| 0 | MGO | SERVICE CONNECTION AT 3 O' CLOCK AT MH |
| 178.2 | TFC | — |
| 340 | TFC | — |
| 310.4 | FM | — |
| 206.4 | TFC | — |
| 176.7 | FM | — |