Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 19, 2019, 05:21 AM
  • 18 1006_18 1005 _03182019_225114.mp4

Date
03/18/2019
W/O
755854
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00677
PipeID
P14860
Time
10:21 PM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6481
Sewer Name
18 LA HABRA HEIGHTS TRUNK, SECTION 1
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_755854_TV18202_MAR2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
18 1006
Downstream MH
18 1005
Dir. of Survey
Downstream
Length Surveyed
265.2 ft.
Total Length
265.2 ft.
Structural Index
3
Structural Quick
514C
Structural Rating
111
O&M Index
2
O&M Quick
2I12
O&M Rating
100
Overall Index
3
Overall Quick
Overall Rating
211
Pipe schematic from manhole 18 1006 to 18 1005
MH: 18 1006MH: 18 1005downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 10060 ft. MGO - General Observation - MULTIPLE CONNETION IN MH0 ft. MWL - Water Level, 20 %of cross sectional area5 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES15.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start34 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES41.4 ft. FM - Fracture Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES56.3 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES60.4 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES61.2 ft. MWLS - Water Level, Sag in pipe, 15 %of cross sectional area, Start68.7 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start74.9 ft. MWLS - Water Level, Sag in pipe, 15 %of cross sectional area, Finish114.6 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish116.9 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES126.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 8"126.8 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area128.5 ft. FS - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES134.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start156.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish164.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES165.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"170.5 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES179.8 ft. FM - Fracture Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES197.9 ft. FS - Fracture Spiral, from 08 to 10 o'clock, within 8 inches of joint: YES210.5 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES224.3 ft. RFJ - Roots Fine Joint, from 08 to 10 o'clock, within 8 inches of joint: YES225.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 8"226.1 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES228.2 ft. B - Broken, from 08 to 09 o'clock, within 8 inches of joint: YES228.2 ft. RFJ - Roots Fine Joint, from 12 to 03 o'clock, within 8 inches of joint: YES228.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"253.7 ft. B - Broken, from 09 to 02 o'clock, within 8 inches of joint: YES256.7 ft. MWLS - Water Level, Sag in pipe, 15 %of cross sectional area262.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish265.2 ft. AMH - Downstream Manhole, Survey Ends - 18 1005

Observation photos (20)

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    5 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    15.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    34 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES

    41.4 ft. - Fracture Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    56.3 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    60.4 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    68.7 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    116.9 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES

    128.5 ft. - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    134.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    164.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES

    179.8 ft. - Fracture Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 08 to 10 o'clock, within 8 inches of joint: YES

    197.9 ft. - Fracture Spiral, from 08 to 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    210.5 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 08 to 10 o'clock, within 8 inches of joint: YES

    224.3 ft. - Roots Fine Joint, from 08 to 10 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES

    226.1 ft. - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Broken, from 08 to 09 o'clock, within 8 inches of joint: YES

    228.2 ft. - Broken, from 08 to 09 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 12 to 03 o'clock, within 8 inches of joint: YES

    228.2 ft. - Roots Fine Joint, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Broken, from 09 to 02 o'clock, within 8 inches of joint: YES

    253.7 ft. - Broken, from 09 to 02 o'clock, within 8 inches of joint: YES

  • Water Level, Sag in pipe, 15 %of cross sectional area

    256.7 ft. - Water Level, Sag in pipe, 15 %of cross sectional area

Observations (36)

DistanceCodeObservation
224.3RFJ
116.9CL
0MWM
126.8TFA
156.6FM
210.5CL
41.4FM
256.7MWLS
5FM
262.6DAGS
61.2MWLS
15.9DAGS
74.9MWLS
68.7FM
126.8MWLS
34CM
226.1FC
265.2AMH18 1005
197.9FS
170.5FL
56.3CL
179.8FM
0AMH18 1006
164.7FM
60.4FM
114.6FM
253.7B
228.2B
128.5FS
0MGOMULTIPLE CONNETION IN MH
225.6TFA
228.6TFA
165.9TFA
228.2RFJ
0MWL
134.7FM

Properties (5)

custom_field_two
1
customer
LACSD
datetime
2019-03-18T22:21:10-07:00
documentation
PROPIPE
is_lateral_inspection
false