21 0789_21 0788_04032019_231751.mp4
0 ft. - Broken, from 01 to 05 o'clock, within 8 inches of joint: YES
45.1 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES
87.9 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES
95.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES
98 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
325.4 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES
333.2 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start
373.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 0 | MWL | — |
| 297.1 | TB | — |
| 0 | MGO | MULTIPLE CONNECTIONS IN MH |
| 325.4 | SSS | — |
| 184.1 | CM | — |
| 98 | CM | — |
| 373.1 | CM | — |
| 333.2 | SSS | — |
| 95.8 | CM | — |
| 0 | AMH | 21 0788 |
| 0 | MWM | — |
| 147.8 | TBA | — |
| 45.1 | CL | — |
| 407.5 | AMH | 21 0789 |
| 373.1 | SSS | — |
| 0 | B | — |
| 87.9 | CM | — |