Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 8, 2019, 06:19 AM
  • 22 0283_22 0282_02072019_223331.mp4

Date
02/07/2019
W/O
745519
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00793
PipeID
P16569
Time
10:19 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6387
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
31
Purpose
Routine Assessment
Project
RFIR_WO_745519_TV22014_JAN2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0283
Downstream MH
22 0282
Dir. of Survey
Downstream
Length Surveyed
105.9 ft.
Total Length
105.9 ft.
Structural Index
3
Structural Quick
3C2C
Structural Rating
105
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
108
Pipe schematic from manhole 22 0283 to 22 0282
MH: 22 0283MH: 22 0282downstream0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 02832 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start6.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"26.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"91.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"105.9 ft. MWL - Water Level, 50 %of cross sectional area105.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish105.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish105.9 ft. MSA - Survey Abandoned - DUE TO DEBRIS105.9 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - DEBRIS

Observations (13)

DistanceCodeObservation
0MWL
105.9MWL
0MWM
2SAP
26.7TFA
105.9SSS
0AMH22 0283
2SSS
105.9SAP
6.5TFA
105.9MSADUE TO DEBRIS
105.9DSZDEBRIS
91.2TFA

Properties (6)

additional_info
SC365698
custom_field_two
5
customer
LACSD
datetime
2019-02-07T22:19:54-08:00
documentation
PRO PIPE
is_lateral_inspection
false