Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 7, 2019, 05:03 AM
  • 01 1081_01 0943_03062019_222549.mp4

Date
03/06/2019
W/O
750757
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00210
PipeID
P01930
Time
9:03 PM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6464
Sewer Name
01 HUNTINGTON PARK TRUNK
City
CUDAHY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_750757_TV01246_FEB2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
01 1081
Downstream MH
01 0943
Dir. of Survey
Downstream
Length Surveyed
381.4 ft.
Total Length
381.4 ft.
Structural Index
3
Structural Quick
4335
Structural Rating
33
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
3
Overall Quick
Overall Rating
34
Pipe schematic from manhole 01 1081 to 01 0943
MH: 01 1081MH: 01 0943downstream0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 10818.1 ft. CM - Crack Multiple, from 02 to 03 o'clock, within 8 inches of joint: YES12.9 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES15.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start174.6 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area182.3 ft. LL - Alignment Left, 5 %183.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish193 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES212.8 ft. CS - Crack Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES, Start286.7 ft. CS - Crack Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish286.7 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES290 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES292.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start333 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish369.6 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES372 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES380.9 ft. MGO - General Observation - SERVICE CONNECTION AT 9 O'CLOCK AT MH381.4 ft. AMH - Downstream Manhole, Survey Ends - 01 0943

Observation photos (13)

  • Crack Multiple, from 02 to 03 o'clock, within 8 inches of joint: YES

    8.1 ft. - Crack Multiple, from 02 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    12.9 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    15.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Water Level, Sag in pipe, 10 %of cross sectional area

    174.6 ft. - Water Level, Sag in pipe, 10 %of cross sectional area

  • Alignment Left, 5 %

    182.3 ft. - Alignment Left, 5 %

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    193 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    212.8 ft. - Crack Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

  • Crack Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish

    286.7 ft. - Crack Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    286.7 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    290 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    292.1 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    369.6 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    372 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
212.8CS
380.9MGOSERVICE CONNECTION AT 9 O'CLOCK AT MH
15.7FM
292.1CM
12.9FM
183.8FM
0MWL
369.6FM
372FL
286.7CS
182.3LL
193CM
0MWM
174.6MWLS
0AMH01 1081
286.7CM
333CM
8.1CM
290CL
381.4AMH01 0943

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-03-06T21:03:37-08:00
documentation
PROPIPE
is_lateral_inspection
false