Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 30, 2019, 09:05 AM
  • 18 0457_18 0456_01302019_012253.mpg

Date
01/30/2019
W/O
745744
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00691
PipeID
P14309
Time
1:05 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6373
Sewer Name
18 NORTH PLANT OUTFALL TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_745744_TV18140_JAN2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
18 0456
Downstream MH
18 0457
Dir. of Survey
Upstream
Length Surveyed
499.2 ft.
Total Length
499.2 ft.
Structural Index
3
Structural Quick
3S00
Structural Rating
294
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
298
Pipe schematic from manhole 18 0456 to 18 0457
MH: 18 0456MH: 18 0457upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 04570 ft. MGO - General Observation - CONNECTION AT MH 3 OCLOCK2.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish492.6 ft. MGO - General Observation - MAG COAT493 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start499.2 ft. AMH - Downstream Manhole, Survey Begins - 18 0456499.2 ft. MWM - Water Mark, 50 %of cross sectional area499.2 ft. MWL - Water Level, 35 %of cross sectional area

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
6.6MGOMAG COAT
0AMH18 0456
0MWM
499.2AMH18 0457
0MWL
499.2MGOCONNECTION AT MH 3 OCLOCK
496.7SAP
6.2SAP

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-01-30T01:05:03-08:00
documentation
PROPIPE
is_lateral_inspection
false