Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 30, 2019, 08:21 AM
  • 18 0651_18 0006_01302019_002753.mpg

Date
01/30/2019
W/O
745744
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00691
PipeID
P14313
Time
12:21 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6373
Sewer Name
18 NORTH PLANT OUTFALL TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_745744_TV18140_JAN2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
18 0006
Downstream MH
18 0651
Dir. of Survey
Upstream
Length Surveyed
29 ft.
Total Length
29 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 18 0006 to 18 0651
MH: 18 0006MH: 18 0651upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 06510 ft. MGO - General Observation - CONNECTION AT MH 9 OCLOCK26.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES26.4 ft. MGO - General Observation - MAG COAT29 ft. MWL - Water Level, 40 %of cross sectional area29 ft. MGO - General Observation - CONNECTION AT MH 3 OCLOCK29 ft. MWM - Water Mark, 50 %of cross sectional area29 ft. AMH - Downstream Manhole, Survey Begins - 18 0006

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
2.6SAP
0MWL
29AMH18 0651
29MGOCONNECTION AT MH 9 OCLOCK
0MGOCONNECTION AT MH 3 OCLOCK
0MWM
0AMH18 0006
2.6MGOMAG COAT

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-01-30T00:21:45-08:00
documentation
PROPIPE
is_lateral_inspection
false