Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 24, 2019, 09:20 AM
  • 08 0038_08 0037 _01242019_013121.mpg

Date
01/24/2019
W/O
745602
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00016
PipeID
P00040
Time
1:20 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5347
Sewer Name
08 MAIN STREET TRUNK
City
GARGENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_745602_TV08115_JAN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
08 0037
Downstream MH
08 0038
Dir. of Survey
Upstream
Length Surveyed
167.1 ft.
Total Length
167.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2B00
O&M Rating
32
Overall Index
2
Overall Quick
Overall Rating
32
Pipe schematic from manhole 08 0037 to 08 0038
MH: 08 0037MH: 08 0038upstream0 ft. AMH - Upstream Manhole, Survey Ends - 08 00380.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish0.1 ft. MGO - General Observation - CONNECTION AT MH 9 OCLOCK5.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"54.9 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"79.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start107.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 8"156.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"167.1 ft. MWM - Water Mark, 45 %of cross sectional area167.1 ft. MWL - Water Level, 25 %of cross sectional area167.1 ft. AMH - Downstream Manhole, Survey Begins - 08 0037167.1 ft. MGO - General Observation - CONNECTION AT MH 3 OCLOCK

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    87.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
0MWM
0MWL
167DAGS
10.2TFC
59.4TFA
167MGOCONNECTION AT MH 9 OCLOCK
0AMH08 0037
87.8DAGS
161.3TFC
167.1AMH08 0038
112.2TFC
0MGOCONNECTION AT MH 3 OCLOCK

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2019-01-24T01:20:53-08:00
documentation
PROPIPE
is_lateral_inspection
false