Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 24, 2019, 10:41 AM
  • 08 0031_08 0030 _01242019_032116.mpg

Date
01/24/2019
W/O
745602
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00016
PipeID
P00033
Time
2:41 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5347
Sewer Name
08 MAIN STREET TRUNK
City
GARGENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
07
Purpose
Routine Assessment
Project
RFIR_WO_745602_TV08115_JAN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
08 0031
Downstream MH
08 0030
Dir. of Survey
Downstream
Length Surveyed
332 ft.
Total Length
332 ft.
Structural Index
4
Structural Quick
5146
Structural Rating
32
O&M Index
3
O&M Quick
3J00
O&M Rating
165
Overall Index
3
Overall Quick
Overall Rating
197
Pipe schematic from manhole 08 0031 to 08 0030
MH: 08 0031MH: 08 0030downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 00310 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area7.8 ft. B - Broken, from 12 to 12 o'clock, within 8 inches of joint: YES9.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"58.4 ft. OBZ - Obstacles Other, 15 %of cross sectional area, from 05 to 07 o'clock, Start106.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"155.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"204.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start205 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"234.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish256.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 8"296.9 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES309.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"332 ft. OBZ - Obstacles Other, 15 %of cross sectional area, from 05 to 07 o'clock, Finish332 ft. AMH - Downstream Manhole, Survey Ends - 08 0030

Observation photos (3)

  • Broken, from 12 to 12 o'clock, within 8 inches of joint: YES

    7.8 ft. - Broken, from 12 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    204.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    296.9 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
0AMH08 0031
106.5TFC
205TFC
9.4TFC
7.8B
309.3TFC
332OBZ
58.4OBZ
204.4FM
256.8TFA
0MWL
332AMH08 0030
234.8FM
296.9CM
0MWM
155.5TFC

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-01-24T02:41:42-08:00
documentation
PROPIPE
is_lateral_inspection
false