- Date
- 02/13/2019
- W/O
- 745602
- Weather
- Light Rain
- Operator/Surveyor
- E.RUIZ
- Sewer ID
- Z00016
- PipeID
- P00010
- Time
- 10:15 PM
- Certificate
- U-715-07000753
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K6273
- Sewer Name
- 08 MAIN STREET TRUNK
- City
- CARSON
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 07
- Purpose
- Routine Assessment
- Project
- RFIR_WO_745602_TV08115_JAN2019
- Sewer Type
- Gravity
- Material
- RCP-CTL
- Shape
- Circular
- Height
- 33 in.
- Width
- 33 in.
- Upstream MH
- 08 0010
- Downstream MH
- 08 0009
- Dir. of Survey
- Downstream
- Length Surveyed
- 115.8 ft.
- Total Length
- 115.8 ft.
- Structural Index
- 4
- Structural Quick
- 4131
- Structural Rating
- 7
- O&M Index
- 4
- O&M Quick
- 5131
- O&M Rating
- 8
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 15
Pipe schematic from manhole 08 0010 to 08 0009 Observation photos (3)

11.9 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

11.9 ft. - Missing Brick, from 09 to 03 o'clock, Start

61.5 ft. - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES