Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 28, 2019, 11:24 AM
  • 05 1600_05 1599 _01282019_034516.mpg

Date
01/28/2019
W/O
745406
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00485
PipeID
P06824
Time
3:24 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5351
Sewer Name
05 MARICOPA STREET TRUNK
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
25
Purpose
Routine Assessment
Project
RFIR_WO_745406_TV05344_JAN2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
05 1599
Downstream MH
05 1600
Dir. of Survey
Upstream
Length Surveyed
311 ft.
Total Length
311 ft.
Structural Index
3
Structural Quick
3K21
Structural Rating
185
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
3
Overall Quick
Overall Rating
186
Pipe schematic from manhole 05 1599 to 05 1600
MH: 05 1599MH: 05 1600upstream0 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 05 160011.5 ft. MWLS - Water Level, Sag in pipe, 15 %of cross sectional area119 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 8"168 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"172.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 8"228.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"233 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"277.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"281.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"289.1 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES305.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start311 ft. MGO - General Observation - CHANNEL BROKEN311 ft. MWM - Water Mark, 15 %of cross sectional area311 ft. AMH - Downstream Manhole, Survey Begins - 05 1599311 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (1)

  • General Observation - CHANNEL BROKEN

    0 ft. - General Observation - CHANNEL BROKEN

Observations (16)

DistanceCodeObservation
33.7TFA
78TFC
21.9RFJ
0MGOCHANNEL BROKEN
5.9SAP
29.4TFC
299.5MWLS
311SAP
82.2TFC
311AMH05 1600
192TFA
138.9TFA
0MWM
0AMH05 1599
0MWL
143TFC

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-01-28T03:24:09-08:00
documentation
PROPIPE
is_lateral_inspection
false