Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 9, 2019, 08:39 AM
  • 01 0197_01 0196_01092019_005248.mp4

Date
01/09/2019
W/O
740026
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00202
PipeID
P01239
Time
12:39 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5332
Sewer Name
01 COMPTON AVENUE TRUNK
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_740026_TV01237_DEC2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0197
Downstream MH
01 0196
Dir. of Survey
Downstream
Length Surveyed
218.5 ft.
Total Length
218.5 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 01 0197 to 01 0196
MH: 01 0197MH: 01 0196downstream0 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. MGO - General Observation - CAPPED CONNECTION AT 9 O' CLOCK AT0 ft. AMH - Upstream Manhole, Survey Begins - 01 01970 ft. MWL - Water Level, 40 %of cross sectional area7.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start18.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 8"51.9 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 8"54.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 8"63.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 8"83.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 8"110 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"110.7 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 8"115.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"121.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 8"136.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"145.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 8"166.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"200.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 8"215 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish218.5 ft. MGO - General Observation - SERVICE CONNECTION AT 3 O' CLOCK AT MH218.5 ft. AMH - Downstream Manhole, Survey Ends - 01 0196

Observation photos (1)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    7.1 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (21)

DistanceCodeObservation
110.7TF
110TFC
0MWM
54.2TFA
115.7TFC
166.1TFC
218.5MGOSERVICE CONNECTION AT 3 O' CLOCK AT MH
18.5TFA
0MGOCAPPED CONNECTION AT 9 O' CLOCK AT
200.2TF
63.2TFA
51.9TFD
218.5AMH01 0196
0AMH01 0197
83.4TF
136.4TFC
121.5TF
145.2TF
7.1CM
215CM
0MWL

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-01-09T00:39:17-08:00
documentation
PROPIPE
is_lateral_inspection
false