Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 9, 2019, 05:39 AM
  • 01 0185A_01 0185_01082019_214420.mp4

Date
01/08/2019
W/O
740026
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00202
PipeID
P01227
Time
9:39 PM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5332
Sewer Name
01 COMPTON AVENUE TRUNK
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_740026_TV01237_DEC2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0185
Downstream MH
01 0185A
Dir. of Survey
Upstream
Length Surveyed
18.4 ft.
Total Length
18.4 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 01 0185 to 01 0185A
MH: 01 0185MH: 01 0185Aupstream0 ft. AMH - Upstream Manhole, Survey Ends - 01 0185A0 ft. MGO - General Observation - SERVICE CONNECTION AT 3 O' CLOCK AT MH1.8 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish12.5 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start18.4 ft. MWM - Water Mark, 10 %of cross sectional area18.4 ft. MWL - Water Level, 10 %of cross sectional area18.4 ft. AMH - Downstream Manhole, Survey Begins - 01 018518.4 ft. MGO - General Observation - SERVICE CONNECTION AT 9 O'CLOCK AT MH

Observation photos (1)

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    5.9 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWM
16.6FM
5.9FM
0MWL
18.4AMH01 0185A
18.4MGOSERVICE CONNECTION AT 3 O' CLOCK AT MH
0AMH01 0185
0MGOSERVICE CONNECTION AT 9 O'CLOCK AT MH

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-01-08T21:39:32-08:00
documentation
PROPIPE
is_lateral_inspection
false